Test recommended to maintain cooling water within the prescribed limits.
Nitrite - Recommended Limits can be in the range of 700-2400 ppm as NO2. Please refer to the inhibitor Product Data Sheet for product specific control limits. The nitrite concentration should be maintained within the above recommended limits to effectively inhibit any corrosive or scaling action within a closed cooling system. Too high a concentration should be avoided to minimize the cost to maintain the system. Insufficient dosage can set up a condition where accelerated corrosion can occur in areas which become unprotected.
pH - Recommended Limits 8.3-10. The effectiveness of a corrosion inhibitor is restricted to within a certain pH range. Treatment ensures that this pH range is observed when the nitrite level is sufficiently maintained to prevent corrosion.
Chlorides - Recommended limit max. 50 ppm. The chloride value of the cooling water should be kept as low as possible, any increase in value whether sudden or gradual, will be an indication of sea water contamination. Check with engine manufacturer for other specified limits. If the chloride level exceeds 50 ppm, the possibility of corrosion in the system increases because chlorides have a negative effect on the passivation film created by nitrites. Therefore, until corrective action has succeeded in bringing the chloride level back down below 50 ppm, the nitrite level should be kept close to the upper limit (2400 ppm).
Supplied with
Instruction sheet, 1 x Stirring Rod, 1 x 5ml Syringe, pH Test Papers 6.6-10 pk. 100, 1 x 100ml shaker tube, Chloride Test Tablets btl. 250, Nitrite No.1 Test Tablets btl. 100, Nitrite No.2 Test Tablets btl. 250.
Features
- Sturdy plastic case
- Simple to use test kit
- Test methods included
Benefits
- Helps to maintain optimum corrosion protection
- Protects valuable equipment assets
UNITOR的冷却水处理程序
订货编号EDP739466
在使用Rocor NB Liquid时,维持水在规定范围之内建议作如下化验:
亚硝酸盐—建议范围1000—2400PPm NO2
建议亚硝酸盐的浓度应当维持在上述范围之内,这样可以在冷却系统开关时,能有效地抑制各种腐蚀作用或形成水垢。要避免浓度太高,降低系统的保养成本。给药量不足,可能引起腐蚀加速,甚至可能无法得到保护。应当根据所推荐的亚硝酸盐水平,合理使用Rocor NB Liquid.
HP值—建议范围8.3-10
腐蚀抑制剂的效力在一定的PH值范围之内才能发挥作用。用Rocor nb Liquid处理剂可以确保PH值维持在一个范围内,从而防止发生腐蚀。在某些情况下,由于外部的污染,即使正确使用亚硝酸盐的量,PH值也可能不在正常范围之内,在这种情况下,Unitor建议,当PH值低于8.3时,在每吨冷却水中加进50毫升的Unitor ALKALINITY CONTROL(碱性控制剂),可以提高PH值。加量后,再次测定PH值,确保PH值维持在8.3-10.0之间。
氯化物-建议最高含量为50ppm
冷却水的氯化物含量应保持尽可能低,氯含量增加,无论是突发性还是渐进性的增加都表明受到了海水的污染。这时,要按照柴油机制造商对其他特定的范围进行检查。如果氯化物水平超过50ppm,系统中腐蚀的可能将大大增加,这是由于氯化物对亚硝酸盐形成的钝化膜有负面的影响。因此,只有当严硝酸盐水平牢牢地保持在上限(2400ppm),氯化物水平回落到50ppm以下之后,才能产生保护作用。
柴油机的采样
在每台柴油机的所有冷却系统上都应当有可供使用的采样阀。这包括,但不限于,主缸套水、活塞冷却、燃油阀门、付机、低温系统等等。一个有代表性的样品必须采自每外待测的冷却水系统。为了毫不费力地采到冷却水样,要求装在规定位置的放样阀,具有迅速和容易放样的通道,使采样很容易进行。每次采样时,样品瓶都应盛满等测试的水,然后密封好并贴上标签。最好在采样30分钟内进行必要的测试。但是,如果样品瓶为水样完全灌满并且密封对良好,可以延长一些时间也无防。
SPECTRAPAK 309冷却水化验程序
冷却水处理剂 亚硝酸盐,氯化物和PH值
亚硝酸盐化验
1.用注射器取5毫升水样注入提供的容器内。
2.用蒸盐水将样品稀释至50毫升。
3.加进两粒亚硝酸盐Ⅰ号片剂,摇碎(或用提供的棒压碎),试样成白色。
4.加1粒亚硝酸盐2号片剂,摇碎。
5.继续加进亚硝酸盐2号片剂,每次1粒,直到至少1分钟内粉红色不消失为止。
计算
亚硝酸盐(ppm)=2号药片数×180
例如:若用了9片,
亚硝酸盐-9×180=1620ppm
6.将所得结果记在提供的记盐纸上,注明测试日期。
氯化物化验
1.取50毫升水样置于提供的容器内。
2.加1粒氯化物片剂,摇碎,如果有氯化物,样品将呈黄色。
3.重复加进片剂,每次1粒,直到黄色变成橙色/棕色。
计算
氯化物ppm=(所用药片数×20)-20=40ppm
例如:若用了3粒,
即氯化物ppm=(3×20)-20=40ppm
4.将所行结果记录在提供的记录纸上,标明测试日期。